The Kamo Seiko MINITABLE is a precise indexing table featuring extremely high positioning accuracy in a very compact and robust package. The table rotation is uniform, with rotating torque being proportional to air pressure applied. A simple four-way valve arrangement allows the MINITABLE to be installed easily with a wide range of applications in mind. Due to the locking pin mechanism utilized, the MINITABLE provides holding torque and accuracy compatible with its performance. With either base mounting or flange mounting available as standard, the MINITABLE can be mounted in various orientations without sacrificing performance.

  PLUMBING METHOD   INDEXING METHOD
Plumbing Method Diagram Indexing Method Diagram
  INTERNAL CONSTRUCTION

Internal Construction Diagram

  SPECIFICATIONS Note: Indexing torque must be reduced by 40% of rated torque in models with two (2) index stops.

Model Unit MT70 MT100 MT125 MT200 Notes
Index Number Stops 2,3,4,5,6 2,3,4,5,6,8 2,3,4,5,
6,8,10,12
3,4,5,6,
8,10,12,16
16 stops is semi-standard
Index Speed seconds 0.5 0.8 1.0 1.5 no load value
Index Accuracy arc • min ±4 ±3 ±2 ±1 arc minutes
Max Load Weight kg
lbs
1
(2.2)
3
(6.6)
15
(33)
35
(77)
high speed not achievable
when at full load weight
Maximum Air Pressure kg/cm²
(psi)
7
(100)
7
(100)
7
(100)
7
(100)
(psi)
Index Torque N • m
(lb • in)
1.96
(17)
11.7
(104)
29.4
(260)
98
(867)
air pressure @ 60 psi
Internal Volume cm³
(ci)
36
(2.2)
250
(15)
500
(30)
1300
(79)
cubic inches
Body Weight kg
(lbs)
2
(4.4)
5
(11)
10
(22)
30
(66)
 
Platen Diameter MM
(in)
120
(4.8)
180
(7.2)
250
(10)
400
(16)
maximum recommended diameter
Rotating Direction DIR R • L R • L R • L R • L when viewed from
rotating source
Minimum Holding Torque N • m
(lb • in)
2.9
(26)
11.7
(104)
29.4
(260)
98
(867)
 
Maximum Load Inertia kg•cm²
(in•lb•sec²)
75
(.07)
500
(.44)
5000
(4.4)
30,000
(26.5)
See inertia formula for definition
Operating Load - Thrust Load N
(lbs)
98
(22)
980
(220)
2940
(660)
4900
(1100)
Maximum external load of
stopped table
Operating Load - Radial Load N
(lbs)
29
(6.6)
245
(55)
490
(110)
1960
(440)
Maximum external load of
stopped table
Lubrication   NR NR NR NR  

  DIMENSIONS Note: Rotation shown by arrow is left. When designing, observe
the mounting hole position as reference to index start mark.

standard Dimensions Diagram
Standard

Flange Dimensions Diagram
Flange

  MT SERIES DIMENSIONS

Model No. \ Letter A B C D E F G H I J K L M N P Q S
MT70S 98 105 70 72 8 15 40 14 8 60 86 M 5
x 8
6x15º M5 3
MT70F 98 100 70 72 8 10 40 15 5 60 86 M 5
x 8
6 M 5 3 5
MT100S 130 125 100 105 12 22 48 19 10 90 115 M 6
x 10
6.5x15º M 6
x 10
RC1/8 7
MT100F 134 120 100 105 12 17 48 16 6 90 120 M 6
x 10
6.5 M 6
x 10
RC1/8 7 6
MT125S 155 150 120 125 20 22 68 19 10 110 140 M 6
x 10
9x15º M 6
x 12
RC1/4 7
MT125F 160 145 120 125 20 17 68 15 8 110 144 M 6
x 10
9 M 6
x 12
RC1/4 7 6
MT200S 230 185 180 190 25 32 70 30 12 160 205 M 10
x 20
11x6º M 10
x 15
RC1/4 13
MT200F 240 180 180 190 25 27 70 24 12 160 220 M 10
x 20
11x6º M 10
x 15
RC1/4 13 6

All dimensions are metric

  MODEL SELECTION

MT (70, 100, 125, 200), (S, F), (NUMBER OF INDEXES), (R, L)


Example: MT70-S-4 - R is defined as a Model MT70 with a Standard mount, 4 stops and rotating to the Right when viewed from the top.

  INERTIA / INDEX TIME RELATIONSHIP

When designing the MINITABLE into an application, the load inertia, JL should be within the specified values. There is a correlation between indexing time and load inertia so care should be taken when determining the MINITABLE model and the indexing time to inertia load relationship. The indexing time listed in the specifications is a no load time. The index time for a load of maximum JL is set for 3 seconds. Calculated values of JL should be proportionally distributed between the no load index time and the 3 second maximum load time.

Diagram of Inertia/Index Time Relationship

  AIR PRESSURE / INDEX TORQUE RELATIONSHIP

In order to maintain long-term reliability in the MINITABLE selected, it is advised that the units be operated within the area shown in the charts below.

Charts of Air Pressure / Index Torque Relationship
 

 

Navigation