MINITABLE CHARACTERISTICS
The Kamo Seiko MINITABLE is a precise indexing table featuring
extremely high positioning accuracy in a very compact and robust
package. The table rotation is uniform, with rotating torque being
proportional to air pressure applied. A simple four-way valve
arrangement allows the MINITABLE to be installed easily with a wide
range of applications in mind. Due to the locking pin mechanism
utilized, the MINITABLE provides holding torque and accuracy
compatible with its performance. With either base mounting or flange
mounting available as standard, the MINITABLE can be mounted in
various orientations without sacrificing performance.
PLUMBING METHOD |
INDEXING METHOD |
 |
 |
INTERNAL CONSTRUCTION

SPECIFICATIONS |
Note: Indexing torque must be reduced by
40% of rated torque in models with two (2) index stops. |
| Index Number |
Stops |
2,3,4,5,6 |
2,3,4,5,6,8 |
2,3,4,5,
6,8,10,12 |
3,4,5,6,
8,10,12,16 |
16 stops is semi-standard |
| Index Speed |
seconds |
0.5 |
0.8 |
1.0 |
1.5 |
no load value |
| Index Accuracy |
arc • min |
±4 |
±3 |
±2 |
±1 |
arc minutes |
| Max Load Weight |
kg
lbs |
1
(2.2) |
3
(6.6) |
15
(33) |
35
(77) |
high speed not achievable
when at full load weight |
| Maximum Air Pressure |
kg/cm²
(psi) |
7
(100) |
7
(100) |
7
(100) |
7
(100) |
(psi) |
| Index Torque |
N • m
(lb • in) |
1.96
(17) |
11.7
(104) |
29.4
(260) |
98
(867) |
air pressure @ 60 psi |
| Internal Volume |
cm³
(ci) |
36
(2.2) |
250
(15) |
500
(30) |
1300
(79) |
cubic inches |
| Body Weight |
kg
(lbs) |
2
(4.4) |
5
(11) |
10
(22) |
30
(66) |
|
| Platen Diameter |
MM
(in) |
120
(4.8) |
180
(7.2) |
250
(10) |
400
(16) |
maximum recommended diameter |
| Rotating Direction |
DIR |
R • L |
R • L |
R • L |
R • L |
when viewed from
rotating source |
| Minimum Holding Torque |
N • m
(lb • in) |
2.9
(26) |
11.7
(104) |
29.4
(260) |
98
(867) |
|
| Maximum Load Inertia |
kg•cm²
(in•lb•sec²) |
75
(.07) |
500
(.44) |
5000
(4.4) |
30,000
(26.5) |
See inertia formula for
definition |
| Operating Load - Thrust
Load |
N
(lbs) |
98
(22) |
980
(220) |
2940
(660) |
4900
(1100) |
Maximum external load of
stopped table |
| Operating Load - Radial
Load |
N
(lbs) |
29
(6.6) |
245
(55) |
490
(110) |
1960
(440) |
Maximum external load of
stopped table |
| Lubrication |
|
NR |
NR |
NR |
NR |
|
DIMENSIONS |
Note: Rotation shown by arrow
is left. When designing, observe
the mounting hole position as reference to index start mark. |
Standard
Flange
MT SERIES DIMENSIONS
| MT70S |
98 |
105 |
70 |
72 |
8 |
15 |
40 |
14 |
8 |
60 |
86 |
M 5
x 8 |
6x15º |
— |
M5 |
3 |
— |
| MT70F |
98 |
100 |
70 |
72 |
8 |
10 |
40 |
15 |
5 |
60 |
86 |
M 5
x 8 |
6 |
— |
M 5 |
3 |
5 |
| MT100S |
130 |
125 |
100 |
105 |
12 |
22 |
48 |
19 |
10 |
90 |
115 |
M 6
x 10 |
6.5x15º |
M 6
x 10 |
RC1/8 |
7 |
— |
| MT100F |
134 |
120 |
100 |
105 |
12 |
17 |
48 |
16 |
6 |
90 |
120 |
M 6
x 10 |
6.5 |
M 6
x 10 |
RC1/8 |
7 |
6 |
| MT125S |
155 |
150 |
120 |
125 |
20 |
22 |
68 |
19 |
10 |
110 |
140 |
M 6
x 10 |
9x15º |
M 6
x 12 |
RC1/4 |
7 |
— |
| MT125F |
160 |
145 |
120 |
125 |
20 |
17 |
68 |
15 |
8 |
110 |
144 |
M 6
x 10 |
9 |
M 6
x 12 |
RC1/4 |
7 |
6 |
| MT200S |
230 |
185 |
180 |
190 |
25 |
32 |
70 |
30 |
12 |
160 |
205 |
M 10
x 20 |
11x6º |
M 10
x 15 |
RC1/4 |
13 |
— |
| MT200F |
240 |
180 |
180 |
190 |
25 |
27 |
70 |
24 |
12 |
160 |
220 |
M 10
x 20 |
11x6º |
M 10
x 15 |
RC1/4 |
13 |
6 |
All dimensions are metric
MODEL SELECTION
MT (70, 100, 125, 200), (S, F), (NUMBER OF INDEXES), (R, L)
|
Example: MT70-S-4 - R is defined as a Model MT70 with a
Standard mount, 4 stops and rotating to the Right when viewed
from the top. |
INERTIA / INDEX
TIME RELATIONSHIP |
When designing the MINITABLE into an application, the load
inertia, JL should be within the
specified values. There is a correlation between indexing time
and load inertia so care should be taken when determining the
MINITABLE model and the indexing time to inertia load
relationship. The indexing time listed in the specifications
is a no load time. The index time for a load of maximum JL
is set for 3 seconds. Calculated values of JL
should be proportionally distributed between the no load index
time and the 3 second maximum load time. |
 |
AIR
PRESSURE / INDEX TORQUE RELATIONSHIP
In order to maintain long-term reliability in the MINITABLE
selected, it is advised that the units be operated within the area